WSF_FT_EFFECT

effect WSF_FT_EFFECT
...
   effect <effect-name> WSF_FT_EFFECT
      ... WSF_PULSE_EFFECT Commands ...
      false_target_name <string-value>
      jamming_pulse_density <real-value>
      scan_rate_multiplier <real-value>
      system_type_data <system-type-name> ... end_system_type_data
   end_effect
...

Overview

This base effect type can be included in the electronic_protect or electronic_attack technique block as one of the many available effects for a given technique. The commands listed below are the base-type commands that can be specified in the effect block for this effect type.

Commands

false_target_name <string-value>

Specifies the false-target name of the false_target definition to be used by this effect.

Note

If not specified then automatic generation of false-targets will be done and default radar parameters will be used in conjunction with the default_pulse_density to generate false-targets. The radar transmitter is required to have the pulse_width and pulse_repetition_interval defined for automatic generation of false-targets.

jamming_pulse_density <real-value>
jamming_duty_cycle <real-value>

Specifies the jammer pulse density in range [0,1] for generating false targets. This input will override the specified quantity if a false target name is input. This input is used to calculate the number of false targets according to the following:

NumberOfFalseTargets = (PRI/PW) * (ScanTime/PRI) * NumberPulsesIntegrated * jamming\_pulse\_density\, NumberOfPulsesIntegrated = MaximumOf(number\_of\_pulses\_integrated,  (AzBeamWidth/ScanRate)/PRI)\,

Default: 0.1

scan_rate_multiplier <real-value>

Specifies the false target generation scan rate multiplier for regenerating false targets. This input will be multiplied by the specified scan_rate if a false target name is input, else the scan rate of the false targets is equal to the frame_time times the scan_rate_multiplier.

Default: 1.0

system_type_data <system-type-name> … end_system_type_data

Input block to provide the system type (e.g., SENSOR-TYPE, JAMMER-TYPE) specific data necessary to implement this technique for a given system type. Default data can be set up for system types not defined using the “default” string as the system type.

  system_type_data <system-type-name>
     ... WSF_PULSE_EFFECT Commands ...
     false_target_name <string-value>
     jamming_pulse_density <real-value>
     scan_rate_multiplier <real-value>
  end_system_type_data

<system-type-name>
    A string input of the system-type the following data applies to, valid values are
    [system-type-name | "default"]. Default data is used for unspecified system-types and if not defined no effect will
    be applied for the given system-type.